New Zealand Delivery |
Hot Water Sorted
Heat pump hot water

Heat pump hot water cylinders: every model, measured

9 heat pump water heaters from Haier, Rinnai, Rheem and Thermann, with the COP, noise, lowest working temperature and electrical supply each one needs. Supply only, delivered anywhere in New Zealand, free.

Models
9
From, incl GST
$3,650
Best rated (Rheem)
COP 5.2
Coldest working (split)
-15°C

Side by side

Model Litres Type Size (mm) COP Noise Works down to Cylinder warranty Price incl GST
Rheem AmbiPower MDc-180 (A551180C5)
Rheem AmbiPower Heat Pump 180L
180 Monoblock 532 w x 1810 h x 576 d — — — 7 yr $4,710
Haier HP200M1U1
Haier Heat Pump Cylinder 200L
200 Monoblock 600 dia x 1658 high 4.49 43 dB at 1 m -7°C 7 yr $3,830
Haier HP250M1U1
Haier Heat Pump Cylinder 250L
250 Monoblock 600 dia x 1951 high 4.48 43 dB -7°C 7 yr $4,090
Thermann 270THMB36
Thermann Heat Pump 270L R290
270 Monoblock 640 dia x 2010 high — — — 5 yr $5,700
Rinnai ME275685E20H
Rinnai HydraHeat Heat Pump 275L
275 Monoblock 685 dia x 1265 high 4.7 45 dB(A) — 7 yr $5,990
Rheem AmbiPower 280e (A551E280R5)
Rheem AmbiPower Heat Pump 280e
280 Monoblock 696 w x 1832 h x 725 d 5.2 — -6°C 7 yr $5,940
Haier HP300S2-F7
Haier Heat Pump Split System 300L
300 Split 580 w x 1694 h x 622 d — 52 dB at 1 m -15°C 7 yr $3,650
Haier HP330M1U1
Haier Heat Pump Cylinder 330L
330 Monoblock 710 dia x 1941 high 4.00 47 dB -7°C 7 yr $4,360
Rinnai ME340685E20H
Rinnai HydraHeat Heat Pump 340L
340 Monoblock 685 dia x 1520 high 4.7 45 dB(A) — 7 yr $7,310

COP figures are the manufacturer's rated test points, and they are not all measured the same way: Haier at 20°C air heating 15 to 55°C water, Rinnai at 19°C air and water in eco mode, Rheem over a full heat-up at 19°C air. Use them to rank like with like, not as a running cost promise. A dash means the manufacturer does not publish that figure.

Monoblock or split

Monoblock units (Haier HP200M1U1, HP250M1U1, HP330M1U1, Rinnai HydraHeat, Rheem AmbiPower, Thermann 270THMB36) carry the compressor on top of the tank, so the whole unit goes outside. Plan the pad: the Haier 330L is 710 mm across and 1941 mm tall, and Haier recommend a poured pad for it rather than pavers.

Split (Haier HP300S2-F7) keeps the 580 x 1694 mm tank where the old cylinder was and puts only the 780 x 545 x 286 mm outdoor unit outside. It is the one to use where there is no room outside for a full tank, and it runs down to -15°C.

Electrical

  • Haier HP200M1U1 and HP250M1U1 can reuse an existing 15 A cylinder circuit.
  • Haier HP330M1U1 needs a dedicated 20 A circuit.
  • For the other models, check the installation guide linked on each product page before quoting the electrical.

Haier install kits

The Haier combo packs bundle the cylinder with the valve set, SimpleFix seismic restraint brackets and a base pad, so one order covers the parts for a standard monoblock install:

Buying from us

  • Prices include GST. Supply only; installation is quoted separately (Auckland).
  • Delivery anywhere in New Zealand is free on any order with a heat pump, or collect free from one of 30 pickup points.
  • Ships in 5 to 10 working days. Haier outside Auckland: email us first so we can check stock.